Wall Energy Balance

The wall energy balance describes heat transfer between the packed bed wall and its surroundings.

Cp,WρWTWt2rihiro2ri2(TTW)+2rohoro2ri2(TWTamb)Kw2TWz2=0C_{p,W} \rho_W \frac{\partial T_W}{\partial t} - \frac{2 r_i h_i}{r_o^2 - r_i^2} (T - T_W) + \frac{2 r_o h_o}{r_o^2 - r_i^2} (T_W - T_{amb}) - K_w \frac{\partial^2 T_W}{\partial z^2} = 0
SymbolDescriptionUnit
Cp,WC_{p,W}Wall heat capacityJ kg⁻¹ K⁻¹
ρW\rho_WWall material densitykg m⁻³
TWT_WWall temperatureK
TTGas/Adsorbent temperatureK
TambT_{amb}Ambient temperatureK
hih_iInternal heat transfer coefficient (gas–wall)W m⁻² K⁻¹
rir_iInternal wall radiusm
hoh_oExternal heat transfer coefficient (wall–ambient)W m⁻² K⁻¹
ror_oExternal wall radiusm
KwK_wWall axial thermal conductivityW m⁻¹ K⁻¹